Claas Jaguar 990 960 Terra Trac (499) Forage Harvesters Technical System EN
$80.00
- Brand: Claas
- Model: Jaguar 990 960 Terra Trac (499) Forage Harvesters
- Type Of Manual: Technical System
- Language: EN
- Format: PDF(s)
- Size: 298 MB
File List:
00 0302 343 1.pdf
00 0302 565 2.pdf
00 0303 118 1.pdf
00 0303 159 3.pdf
00 0303 624 1.pdf
00 0305 018 1.pdf
00 0305 863 0.pdf
CHP-numbers for connectors CLAAS HARNESS PARTS.pdf
00 0302 343 1.pdf:
PROFI CAM 3
Table of contents
General information
Marking of warnings and hazard prevention notes
First-aid measures
CCN explanation
CCN (CLAAS Component Number)
Electric system standard
Overview
Hydraulic system standard
Overview
CCN (CLAAS Component Number)
10 Electrical / Electronic equipment
1030 Board computer / Indicators
Camera system
Description of function
1097 Testing / Measuring / Adjusting
Testing / measuring / adjusting the PROFI CAM
Checking the fuse in the video channel select box (C102)
Testing the video camera connector (C055)
1098 Fault / remedy
Fault / remedy PROFI CAM
The video monitor (C101) shows no image or cannot be switched on (indicator light fails to light up)
Video monitor (C102) displays a blue image either permanently or temporarily
The video monitor image is blurred
Replacing the fuse in the video channel select box (C102)
Connection and connecting cable with video camera (C055)
00 0302 565 2.pdf:
Sensor system
Table of contents
CCN explanation
CCN (CLAAS Component Number)
Electric system standard
Overview
Hydraulic system standard
Overview
CCN (CLAAS Component Number)
Introduction
Safety rules
Safety and hazard information
10 Electrical / Electronic equipment
1097 Testing / Measuring / Adjusting
Test report of the angle sensor (0011780.x)
Application of test report
Required tools
Test report of the angle sensor (0011780.x)
Testing / Measuring / Adjusting of angle sensor (0011780.x)
1. Reason for test
2. Mechanical test of angle sensor
3. Electric test with CDS
4. Electric test with multimeter
5. Mechanical test of connecting cable
Completing the machine
Test report of position and speed sensors
Application of test report
Required tools
Sensor variants
Part numbers of speed sensors
Part number of position sensor
Test report of position and speed sensors
Testing / measuring / adjusting of position and speed sensors
1. Reason for test
2. Mechanical test
3. Electric test with CDS
4a. Installation dimensions
Check of installation dimension
Installation dimensions of gearbox speed sensor (0011 799.x) and cam speed sensor (0011 810.x)
Installation dimension of position sensor (0011 815.x)
4b. Installation position
Centring of sensor
Metal-free zone
5. Electric test with multimeter
Voltage measurement
Direction of rotation and speed sensor (0011 605.x)
Measured values table
6. Mechanical test of connecting cable
Completing the machine
Test report of the urea sensor (00 0773 207 x)
Application of test report
Required tools
Parts number of the urea sensor
Test report of the urea sensor
Testing / measuring / adjusting urea sensor
1. Reason for test
2. Mechanical test
3. Mechanical test of connecting cable
4. Electric test with multimeter
5. Component test with the CDS
00 0303 624 1.pdf:
Table of contents
Introduction
Safety rules
Safety and hazard information
Validity of manual
Validity of manual
21 Feeder unit
2198 Fault / Remedy
Metal detector check list for fault analysis
1. Work schedule for troubleshooting in case of false stops
2. Metal detector is too (in-) sensitive
3. Metal detector causes false stops
3.1 Clarification with customer / workshop if welding work was carried out recently near the cylinder and feeder housings
3.2 Cleaning the cylinder housing and the feeder housing and check if there are any irregularities
3.3 Carrying out a test run at standstill (without front attachment)
3.4 Carrying out a test run at standstill (with front attachment)
3.5 Checking the wiring loom (especially for DTC 0x255b / 0x2554)
3.6 Checking feed rollers / metal detector
3.7 Checking magnetizing of transport housing / feeder housing
3.8 Demagnetizing the transport housing / feeder housing
4. Other remarks
00 0305 863 0.pdf:
LEXIONJAGUARXERION
Table of contents
Introduction
Notes on the manual
Validity of manual
Information about this Technical Systems Manual
Identifying warnings
Hazard signs
Signal word
01 Engine
0125 Injection / Fuel system
Injection / fuel system
Required tools and aids
Line valves for connecting to the engine
Valves and adapters for tank feed and return lines
Measuring setup (possible variant)
Test procedure
A – Leakage test of tank return line and possibly of tank suction line
B – Leakage test of feed lines (possibly including fuel sediment filter)
C – Test of non-return valve in the line (if provided)
D – Leakage test of return lines (possibly including the fuel cooler)
E – Leakage test of fuel sediment filter
F – Leakage test of engine
Steps 1 – 3
Fuel diagrams
Remarks about the circuit diagrams
LEXION fuel diagram
Key to diagram
JAGUAR with Mercedes-Benz OM47x LA
Key to diagram
JAGUAR with MAN D2862 (V12)
Key to diagram
CHP-numbers for connectors CLAAS HARNESS PARTS.pdf:
CLAAS HARNESS PARTS
Table of contents
10 Electrical / Electronic equipment
1081 Overview of connectors
CLAAS HARNESS PARTS (CHP)
Claas Technical System PDF
Claas Technical System PDF